BASIC INFO
Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters
Description of Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters
The AXF magnetic flowmeter is sophisticated product with outstanding reliability and ease of operation, developed on the basis of decades of fieldproven experience.
The AXF magnetic flowmeter is significantly easier to maintain thanks to the combination of replaceable electrodes and a diagnostic function that detects the adhesion level on the electrodes. The AXF also employs a dual frequency excitation method (available for sizes up to 400 mm / 16 in.) that eliminates fluid noise. A newly enhanced dual frequency excitation method is also available as an option for more difficult applications to ensure greater stability and quicker response.
Based on FOUNDATION™ fieldbus specifications, AXF Fieldbus models offer more flexible instrumentation through a higher level communication capability and propose the cost reduction by multi-drop wirings with less cables.
FOUNDATION™ fieldbus is a registered trademark of Fieldbus FOUNDATION.
Note: The “Dual Frequency Excitation Method” is a Yokogawa innovation.
Features of Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters
User-oriented Functionality of Yokogawa ADMAG AXF Magnetic Flowmeters
• Fluid Adhesion Level Diagnosis
The amount of insulating material on the electrode is constantly monitored to determine when maintenance should be performed. An optional replaceable electrode is easy to remove and clean.
• Flexible Electrical Connection Direction
The converter or the terminal box can be rotated in either direction to match the position of the electrical connections at the installation site.
• Clear and Versatile Indications
The large, backlit full dot matrix LCD can display a variety of messages up to three lines in length. When an alarm condition occurs, a full description of the appropriate countermeasure is displayed.
• Easy Setup
The most frequently used parameters are arranged in a group at the top of the display. Infrared switches enable the setting of parameters without opening the cover.
Operation Immediately after Installation
The AXF is shipped with the main parameters completely set and can go into operation as soon as installation and wiring are completed.
Expansion of Product Lineup of Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters
• Improved Accuracy Specification
The standard accuracy is 0.35% of reading. Also available as an option is high accuracy calibration rated at 0.2% of reading.
• Extra Small Size Flange Type
Flange types are now available in sizes as small as 2.5 mm.
• Variety of Sanitary Connections
A wider variety of sanitary connections are now available, including Tri-Clamp, ISO, DIN and SMS.
Enhanced Performance of Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters
• Enhanced Dual Frequency Excitation
The enhanced dual frequency excitation method is available as an option. This provides highly stable measurements involving high concentration slurries or low conductivity fluids.
• Lower Minimum Conductivity.
The newly designed AXF converter permits the measurement of fluids with conductivity as low as 1μS/cm depending on the nominal pipe size and fluid condition.
• High-Speed Pulse Output:
The maximum rate for high speed applications such as short-duration batch processes is now 10,000 pps (pulses per second).
Specification of Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters
AXF Remote Flowtube |
AXF Integral Flow meter |
AXFA14 Converter |
AXFA11 Converter |
|
Size |
2.5 to 400 mm (0.1 to 16 inch) [depends on specifications] |
2.5 to 400 mm (0.1 to 16 inch) [depends on specifications] |
Combined with Remote type flowtube 2.5 to 400mm (0.1 to 16 inch) |
Combined with Remote type flowtube (Note) 2.5 to 400m (0.1 to 16 inch) |
Type of Use |
General-purpose use, Ex-proof type, Sanitary type, Submersible type |
General-purpose use, Ex-proof type, Sanitary type |
General-purpose use, Ex-proof type |
General-purpose use |
Fluid Temp. |
-40 to 160 deg.C (-40 to 320 deg.F) [depends on specifications] |
-40 to 130 deg.C (-40 to 266 deg.F) [depends on specifications] |
- | - |
Ambient Temp. | -40 to 60 deg.C (-40 to 140 deg.F) [depends on model type] | |||
Accuracy | 0.35% of rate (Optional ; 0.2% of rate) | |||
Fluid Conductivity | 1 micro-S/cm or larger (depends on nominal pipe size and fluid condition) | |||
Lining |
Fluorocarbon PFA/Ceramics/Polyurethance Rubber/ EPDM Rubber/ Natural Soft Rubber [depends on model type] |
- | - | |
Process Connection |
Wafer, Flange, Sanitary connections (Clamp[Tri-clamp, DIN, ISO], Union thread[DIN, ISO SMS], Butt-weld), etc. |
- | - | |
Maximum Cable Length | - | - |
100m (330 ft) |
200m (660 ft) |
Indicator | - | Multi line backlit LCD (Full dot-matrix) | ||
Diagnosis | Adhesion diagnosis, Empty pipe, Coil open, etc. | |||
Alarm message |
Alarm message with corrective measures is indicated (English, German, French, Italian, Spanish, Japanese) |
|||
Excitation method |
Dual Frequency Excitation: AXF sizes 2.5 to 400mm, Pulsed DC Excitation: AXW sizes 500 to 1800 mm (Note), Enhanced Dual Frequency Excitation (optional): AXF sizes 25 to 200 mm |
|||
Ex-proof type | ATEX, FM, CSA, IECEx, TIIS | - | ||
Options | Replaceable electrode, Rotatable terminal box(converter), Mirror finished lining surface(for PFA/Ceramics), Special gaskets, etc. |
Ordering Models of Yokogawa Flow Meter AXF002C-D-1-A-E-1-N-AA1-1-2-1-B ADMAG AXF Magnetic Flowmeters:
AXF002C-D-1-A-E-1-N-AA1-1-2-1-B
AXF002C-E-1-A-E-1-N-AA1-1-2-1-B
AXF002C-F-1-A-E-1-N-AA1-1-2-1-B
AXF002C-D-2-A-E-1-N-AA1-1-2-1-B
AXF002C-E-2-A-E-1-N-AA1-1-2-1-B
AXF002C-F-2-A-E-1-N-AA1-1-2-1-B
AXF002C-D-1-C-E-1-N-AA1-1-2-1-B
AXF002C-E-1-C-E-1-N-AA1-1-2-1-B
AXF002C-F-1-C-E-1-N-AA1-1-2-1-B
AXF002C-D-2-C-E-1-N-AA1-1-2-1-B
AXF002C-E-2-C-E-1-N-AA1-1-2-1-B
AXF002C-F-2-C-E-1-N-AA1-1-2-1-B
AXF002C-D-1-A-H-1-N-AA1-1-2-1-B
AXF002C-E-1-A-H-1-N-AA1-1-2-1-B
AXF002C-F-1-A-H-1-N-AA1-1-2-1-B
AXF002C-D-1-A-L-1-N-AA1-1-2-1-B
AXF002C-E-1-A-L-1-N-AA1-1-2-1-B
AXF002C-F-1-A-L-1-N-AA1-1-2-1-B
AXF002C-D-1-A-P-1-N-AA1-1-2-1-B
AXF002C-E-1-A-P-1-N-AA1-1-2-1-B
AXF002C-F-1-A-P-1-N-AA1-1-2-1-B
AXF065G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF065G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF065G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF065G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF065G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF065G-E-1-U-W-1-N-AA1-1-0-1-B/CH
AXF080G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF080G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF080G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF080G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF080G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF080G-E-1-U-W-1-N-AA1-1-0-1-B/CH
AXF100G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF100G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF100G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF100G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF100G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF100G-E-1-U-W-1-N-AA1-1-0-1-B/CH
AXF125G-D-2-A-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-2-A-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-A-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-1-A-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-A-L-1-N-AA1-1-0-1-B/CH
AXF125G-E-1-A-W-1-N-AA1-1-0-1-B/CH
AXF125G-D-2-U-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-2-U-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-U-L-1-N-AA2-1-0-1-B/CH
AXF125G-E-1-U-W-1-N-AA2-1-0-1-B/CH
AXF125G-D-1-U-L-1-N-AA1-1-0-1-B/CH
AXF125G-E-1-U-W-1-N-AA1-1-0-1-B/CH
AXF125C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF125C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF125C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF125C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF100C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF100C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF080C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF080C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-D-2-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-2-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-A-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-A-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-A-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-A-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-D-2-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-2-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-U-L-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-U-W-1-N-AA2-1-0-1-B-/FF1-/G12/CH
AXF065C-D-1-U-L-1-N-AA1-1-0-1-B-/FF1-/G12/CH
AXF065C-E-1-U-W-1-N-AA1-1-0-1-B-/FF1-/G12/CH
We are specialized in intelligent instruments, including : control system, transmitters, flow meters,sensors, recorders, analyzers, control valves, controllers, PLC's, etc.
We mainly supply Yokogawa ,Honeywell,Siemens,ABB,FLUKE,Endress+Hauser,Schneider Electric,Moeller,FUJI,Omron,Pepperl+Fuchs,Hima,Yaskawa, Norgren, Hach, Weidmuller ,Phoenix,MTL,Testo etc.
Why choose us?
1. 100% original product, 100% quality assurance.
If you find a fake. Please contact us without hesitation! We afford the shipment cost! We send you a new product asking zero cent!
2. Varied payment methods.
We adopt T/T, western union and paypal. If you can not trust us , you can choose to pay it via Aliexpress! 100% make your money safe!
3.SHIPPING:
We can shipping all over the world.via DHL,UPS,Fedex,TNT and EMS etc., the packaging is very safe and strong. if you have any special needs,please notify me.
It will take 3 to 7days to reach in your hands.
Packaging:
Imported with original packaging or standard export packing.Customize design is acceptable.
Contact:
HONGKONG XIEYUAN TECH CO., LIMITED
Email:becky@hkxytech.com Web:www.hkxytech.com
Mobile:+86-15972186287(Whatsapp & Wechat)